Mixing station UPM-T for TacoSys underfloor heating manifolds

The mixing station supplies heating manifolds with the required flow rate and in the process regulates and monitors the flow temperature.

Description

The mixing station is a compact pump assembly for direct installation in TacoSys underfloor heating manifolds.
The station is used especially for avoiding installation of a second, costly low-temperature pipework between the boiler and underfloor heating manifold.
The boiler manifold and mixing valve for the underfloor heating loop in the central pump room can also be dispensed with.
When the mixing station is installed directly in the apartment at the heating manifold, adjustments can be performed decentrally for every apartment in accordance with the individual needs of the user and the type of floor covering.
The station therefore guarantees optimal heating comfort for all occupants and ensures safe operation of the system thanks to the external safety temperature limiter. The mixing station can be combined ideally with TacoSys underfloor heating manifolds together with radiator heating systems.

Advantages

Compact

  • Comes equipped with all the necessary valves and components

Secure

  • Intrinsic safety of station with external safety temperature limiter

Simple

  • Simple adjustment and reading of the required flow temperature

Efficient

  • Energy savings thanks to high-efficiency pump

Fitting

  • Fits perfectly to TacoSys under­floor heating manifolds
  • Variants for horizontal or vertical installation

Functions

The required flow temperature can be preset at the heating manifold by means of the integrated thermostatic mixing valve and then regulated subsequently. The pump is switched off by an external safety temperature limiter if the flow temperature of approx. 50°C is exceeded.

Technical Data

General

  • Operating temperature: -10 °C to + 70 °C
  • Max. operating pressure PB max: 6 bar
  • Adjustment range mixing valve: 20 – 50 °C
  • Safety temperature limit 50 °C: ±3%
  • Residual pump head in accordance with flow rate and pressure loss diagrams

Materials

  • Pipes: Stainless steel 1.4400
  • Terminal nuts und eccentric connectors: Brass, nickel-plated
  • Seals: EPDM O-rings

Flow Media

  • Heating water (VDI 2035; SWKI BT 102-01; ÖNORM H 5195–1)
  • Water free of chemical additives

Building categories

All building categories with integrated panel heating combined with radiator heating.

Type Overview

Mixing station UPM-T

Mixing station with UPM-3 high-efficiency pump and external safety temperature limiter
Order no. Delivery head
296.8665.001 7 m